PUB -19386-1000
Page 1 of 4
General Information Specifications
The SeaMetrics AO45 is a compact pulse to analog con-
verter. Combined with an IP insertion flow sensor or a
WT turbine meter, it is ideal for flow rate recording, PLC
or data logger input, and proportional chemical feed. The
unit is available in a wallmount enclosure or in a round
cast-aluminum housing mounted directly on a SeaMetrics
meter. The nonmetallic wallmount enclosure is splash-
proof and has a clear cover.
The 4-20 mA analog output is suitable for telemetry,
metering pump pacing, data logging, or control applica-
tions. Trimpots are used to adjust the 4 mA and 20 mA
setpoints. The unit can be factory-calibrated or user
calibrated with the proper equipment. The output is a 4-
20 mA current source, which is compatible with elec-
tronic metering pumps, programmable controllers and
computer input cards.
Power
Sensor 6-24 VDC
Current loop 12-36 VDC (see chart)
Voltage Burden 11 VDC
Temperature 32° - 130° F (0° - 55° C)
Humidity 85% non-condensing relative
Enclosure
Wall mount polystyrene
Meter mount cast aluminum
Input Open collector transistor
(most SeaMetrics meters)
Frequency range (@ 20 mA output)
Low 10 - 100 Hz
High 100 - 1000 Hz
Output Proportional 4 - 20 mA
Response Time 3 sec. to 95 % output
AO45 Analog Transmitter
Instructions
Features
Calibrationby
factoryorinfield
Meterorwall
mounthousings
Twofrequencyranges
Isolatedor
non-isolatedoutput
DISCONTINUED
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - DISCONTINUED

PUB -19386-1000Page 1 of 4General Information SpecificationsThe SeaMetrics AO45 is a compact pulse to analog con-verter. Combined with an IP insertio

Pagina 2

3. A non-isolated circuit is simpler because it only re-quires one power supply. As a general rule, the stan-dard SeaMetrics PC1 power supply can pow

Pagina 3

Field Calibration. Ordinarily the AO45 is ordered witha flow sensor or meter and is factory calibrated to a re-quested flow range. However, the unit

Pagina 4

20419 80th Ave. So., Kent WA. 98032 USAPhone: 253-872-0284 Fax: 253-872-0285www.seametrics.com 1-800-975-81534-20mAOutput----++++IP Sensor12-24VDC4m